Explore the GMY 80W 172nm VUV excimer lamp. Delivering >85 mW/cm² high irradiance at 3mm with water-cooled stability and an 80mm active emission zone, this mercury-free UV light source is engineered for precision photocleaning, ink curing, and surface activation.

  • Voltage :

    AC>1.3kv
  • Lifespan :

    >1000 hrs
  • Power :

    80W+10%
  • Technical Specifications — Model 172E80D26.5×190

    Electrical & Optical Performance

    Product Model 172E80D26.5×190
    Peak Wavelength 172 nm (Vacuum UV)
    Rated Power 80W ± 10%
    Operating Voltage AC > 1.3 kV
    UV Irradiance (Center @3mm, MC) > 85 mW/cm²
    Average Lifespan > 1,000 hrs
    Glass Surface Temperature < 160°C
    Warm-up Time (to 90% Output) 5 Seconds (Instant-On)
    Test / Operating Atmosphere Nitrogen (N₂) Protection

    Mechanical Dimensions & Integration

    Overall Length (OL) 190 ± 1.5 mm
    Active Emission Length (L1) 80 ± 1.5 mm
    Lamp Tube Diameter (D1) 26.5 + 1 mm
    End Cap Length (L2) 55 ± 0.5 mm
    End Cap Width (W1) 38 ± 0.5 mm
    End Cap Height (H1) 34.5 ± 0.5 mm
    Cooling Method Integrated Water Cooling (Inlet/Outlet Ports)
    Compatible Power Supply MC Series Dedicated Driver
    Primary Applications Photo-Cleaning, Ink Curing, Surface Modification

    Note: Custom engineering modifications for arc length, power rating, and matching high-frequency power supplies are available upon request.

    Product Details & Operating Display

    172nm Excimer Lamp Active Discharge Illumination

    Uniform Plasma Discharge Illumination

    Consistent, high-density dielectric barrier discharge across the 80mm active emission zone, ensuring uniform 172nm VUV irradiation.

    172nm Excimer Lamp

    Precision Water-Cooled Housing & Mesh Electrode

    Machined aluminum end caps with integrated water cooling ports, mounting flanges, and high-transmittance external mesh electrode.

    Compact 80W 172nm Excimer Lamp — High-Intensity VUV Surface Treatment

    Engineered for space-constrained precision equipment, the 172E80D26.5×190 delivers an exceptional UV irradiance exceeding 85 mW/cm² (measured at 3mm) across an 80mm active emission zone. By harnessing direct photochemical oxidation without mercury, this compact emitter strips away stubborn organic residues to achieve atomic-level surface cleanliness on semiconductor wafers, optical lenses, and flat-panel displays.

    Equipped with dedicated water-cooling ports on both end caps and reaching 90% output within just 5 seconds, this dielectric barrier discharge (DBD) light source maintains low glass surface temperatures (<160°C). It provides high-energy 172nm photons that sever molecular bonds and generate reactive oxygen species without subjecting heat-sensitive substrates to thermal warping.

    Why Partner With Us

    • 01. Tailored optical and mechanical specifications matched to your system footprint
    • 02. Fast-track 10-day turnaround from blueprint approval to finished production
    • 03. Zero NRE / development fees | Flexible prototyping starting from a single unit

    Core Application Fields

    Photo-cleaning process Excimer Lamps PROCESS OF CLEANING BY EXCIMER excimer light

    Dry Photo-Cleaning

    High-flux 172nm photons excite surface organic molecules while generating active oxygen radicals, converting contaminants cleanly into volatile H₂O and CO₂. Widely deployed for dry cleaning of semiconductor silicon wafers, LCD/OLED display glass, optical components, AR/VR lenses, and micro-nano fabrication substrates.

    Excimer Ink & Coating Curing

    172nm VUV irradiation triggers ultra-fast surface micro-folding and polymerization under nitrogen protection. This process creates ultra-matte, velvety soft-touch finishes with superior anti-fingerprint and scratch resistance for paint protection films (PPF), packaging inks, furniture panels, automotive interiors, and PCB coatings.

    Photo-curing process Excimer Lamps
    Photo-modification process Excimer Lamps

    Surface Hydrophilic Modification

    Modifies outer molecular groups to dramatically increase surface energy, wettability, and coating adhesion without wet chemicals. Essential for pre-deposition surface activation, MEMS and 3D chip packaging, wafer-to-wafer bonding, and hydrophilic treatment of battery foils and medical implants.

    Key Engineering Advantages

    01 High Irradiance in a Compact Footprint

    Delivers over 85 mW/cm² at 3mm within a 190mm overall length, making it ideal for localized high-speed scanning heads and compact R&D or inline chambers.

    02 Water-Cooled Thermal Stability

    Built-in water cooling channels keep bulb wall temperatures below 160°C, preventing heat transfer to delicate films and ensuring stable VUV intensity over >1,000 hours.

    03 100% Mercury-Free & RoHS Compliant

    Eliminates hazardous mercury vapor from semiconductor and cleanroom lines while providing instant 5-second warm-up without mechanical shutters.

    04 Seamless MC Power Supply Pairing

    Pre-matched with GMY MC-series electronic drivers for reliable ignition (>1.3kV AC), flicker-free plasma discharge, and straightforward PLC automation control.

    Certifications & Compliance

    ISO Certificate
    ISO

    ISO 9001/14001

    Certified quality management framework guaranteeing consistent batch precision.

    CE Certified Declaration
    CE

    CE Certified

    Fully compliant with European health, safety, and environmental protection standards.

    ROHS Compliance Certificate
    RoHS

    ROHS Compliant

    Mercury-free green manufacturing devoid of restricted hazardous substances.

    UL Safety Certificate
    UL

    UL Certified

    Meets rigorous North American electrical safety and fire prevention standards.

    FAQ

    Q Why is nitrogen protection specified for the 172E80D26.5×190 model?

    172nm vacuum UV light is strongly absorbed by oxygen in ambient air. Operating inside a controlled nitrogen (N₂) purge environment prevents premature photon attenuation, maximizes VUV irradiance at the target surface (>85 mW/cm² at 3mm), and prevents oxygen inhibition during excimer ink curing.

    Q How does the water-cooling connection work on this lamp?

    The end caps feature integrated water inlet and outlet ports (38mm × 34.5mm cross-section) that circulate cooling water around the discharge assembly. This keeps the quartz glass surface below 160°C during continuous 80W operation, protecting heat-sensitive substrates from thermal distortion.

    Q Does this lamp require warm-up time before entering an automated conveyor cycle?

    No prolonged warm-up is required. When paired with our MC-series electronic driver, the 172E80D26.5×190 reaches 90% of its rated UV output within just 5 seconds, supporting rapid start-stop synchronization on automated production lines.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Contact Us:jwtan@gmyok.com